Fluke Scopemeter Oscilloscope/2-Channel, 200 MHz Fluke 190-202-III
Condition NE — Condition disclosed — is shown up front on this listing, along with the exact price, current availability, and what certification paperwork ships with the part, so you can confirm fit and airworthiness before you buy. Full specifications and answers to common questions are below.
What does “New” condition mean?
Request certification documents (8130-3 / EASA Form 1 / C of C)
Description
The Fluke ScopeMeter® 190-202 combines the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter test tools go into harsh, dirty, and hazardous industrial conditions to test everything from micro-electronics to power electronics applications.
Included Accessories:
- VPS410 Voltage Probe Sets (one red, one blue)
- TL175 TwistGuardâ„¢ safety designed Test Lead Set (red and black)
- BC190 Battery Charger/mains Adapter
- BP290 2400 mAh Li-ion Battery
- Hand strap (affixed to instrument)
- Hangstrap
- Multi-Language User Manuals on CD-Rom
- FlukeView ScopeMeter® demo package (restricted functionality)
- USB Interface Cable
Features:
- Two electrically isolated inputs
- CAT III 1000V / CAT IV 600V safety rated
- 200 MHz bandwidth model
- 2.5 GS/s
- Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
- Dedicated 5000 Count digital multimeter
- Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
- ScopeRecord roll mode, capture waveform sample data for up to 48 hours
- TrendPlot, trend measurement readings for up to 22 days
- Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
- IP-51 rated for dust and drip proof to withstand harsh environments
- Isolated USB ports for memory devices and PC connectivity
- Li-Ion battery for extended operating timespan
- Easy-access battery door to make it easy to swap batteries
- A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock
Product Codes | |
|---|---|
| Mfr Part No: | FLUKE 190-202-III |
Weight: 2.2 kg Dimensions: 270 x 190 x 70 mm Bandwidth: 200 MHz Number of channels: 200 MHz: 2 channels Real-time sample rate: 2.5 GS/s Inputs: 2 scope plus DMM input Independently floating isolated inputs: Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground Timebase range: 2 ns - 2 min/div Input sensitivity: 2 mV-100 V/div Memory: 2 Channel Screen + Setup: 30 Recording: 10 Display: 153 mm full color LCD with fast update rate Operating temperature: 0°C to 40°C Including Batteries 0°C to 50°C Excluding Batteries Storage Temperature: -20°C to +60°C Operating altitude: Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V Electrical safety: 1,000 V CAT III/600V CAT IV (EN61010-1) Li-Ion battery: BP290 2400 mAh battery up to 4 Hours included standard Warranty: Three years on main instrument, one year on accessories
Specifications
| Part number | FLUKE 190-202-III |
|---|---|
| Manufacturer | Fluke |
| Condition | NE |
| Airworthiness | Condition disclosed |
| Country of origin | — |
| Lead time | days |
Frequently asked
Does the Fluke Scopemeter Oscilloscope/2-Channel, 200 MHz Fluke 190-202-III include certification paperwork?
This item is supplied as "Condition disclosed" rather than with full 8130-3 traceability — normal for some condition codes, and it does not mean the part is unusable, only that the paperwork profile differs. Check the listing for exactly what documentation is included, and request any available records before you purchase if your installation requires them.
What condition is this part?
This part is listed in condition NE — Condition disclosed. Condition codes describe how a part reached its current state (for example new, overhauled, serviceable, repaired, or as-removed) and directly affect what paperwork ships with it and how it should be installed. See the Glossary for the full definition of every condition code we use.
How fast does it ship?
This item is currently on backorder, meaning demand has temporarily outpaced our stock and a new shipment is inbound from the manufacturer or our supplier. Request a quote and we will confirm the current estimated delivery window before you commit. If your aircraft is grounded, AOG expedited handling is available on request.
Can I return it?
You may return this item within 30 days of delivery if it is unopened, uninstalled, and in its original packaging. Items that have been installed, powered on, opened hazmat, or separated from an attached 8130-3 tag are non-returnable because their airworthiness status can no longer be confirmed once removed from the part. See our Returns policy for the full process.
Reviews
No reviews yet — be the first to review the Fluke Scopemeter Oscilloscope/2-Channel, 200 MHz Fluke 190-202-III.
Write a review
Questions & answers
No questions yet — ask the first one about the Fluke Scopemeter Oscilloscope/2-Channel, 200 MHz Fluke 190-202-III.
Ask a question