Warning: Division by zero in /home/aap/public_html/catalog/controller/product/manufacturer.php on line 311 Klixon
.5 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7277-2-1/27277-2 Series Circuit Breaker | 0.5 Amp RatingKlixon 7277-2 series circuit breakers are meant for use in applications that do not require military approvals. The trip-free 7277 was originally developed as an alternative to slow blow fuses and is used extensively as primary electrical circuit protection on general aviation aircraft. The military grade version of this circuit breaker is physically and electrically identical to the Klixon 7277, which has wider calibration limits. Includes hardware.This 7277 series circuit breaker (Alternate Part# 7277-2-1/2) is rated for 0.5 amps. Miniature sizeLight weightTrip free designCurrent ratings (0.5 to 20 amps)High vibration resistanceElectrical circuit protection on general aviation aircraftProduct CodesMfr Part No:7277-2-1/2ECCN:EAR99SCHEDULE B CODE:8536.20.0020Weight: 28 grams, maximum Current Rating: 0.5 Amps Vibrations: 10G minimum, 50–500 Hz Mechanical shock: 35G Acceleration: 10G Interrupt Current: 0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC  400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 2,500 cycles: 30 VDC inductive  5,000 cycles: 120 VAC, 400 Hz resistive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load..
$288.52
.75 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-11-.757274-11 Series Circuit Breaker | 0.75 Amp RatingKlixon® 7274-11 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-11 series circuit breaker (Alternate Part# 7274-11.75) is rated for 0.75 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipment Product CodesMfr Part No:7274-11-.75MIL SPEC:MS22073-3/4ECCN:EAR99MIL SPEC:MS22073-3/4SCHEDULE B CODE:8536.20.0020Weight: 33g, maximum Current Rating: 0.75 amps Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 1.45V @ 0.75A..
$23.13
.75 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7277-2-3/47277-2 Series Circuit Breaker | 0.75 Amp RatingKlixon 7277-2 series circuit breakers are meant for use in applications that do not require military approvals. The trip-free 7277 was originally developed as an alternative to slow blow fuses and is used extensively as primary electrical circuit protection on general aviation aircraft. The military grade version of this circuit breaker is physically and electrically identical to the Klixon 7277, which has wider calibration limits. Includes hardware.This 7277 series circuit breaker (Alternate Part# 7277-2-3/4) is rated for 0.75 amps. Miniature sizeLight weightTrip free designCurrent ratings (0.5 to 20 amps)High vibration resistanceElectrical circuit protection on general aviation aircraftProduct CodesMfr Part No:7277-2-3/4ECCN:EAR99SCHEDULE B CODE:8536.20.0020Weight: 28 grams, maximum Current Rating: 0.75 Amps Vibrations: 10G minimum, 50–500 Hz Mechanical shock: 35G Acceleration: 10G Interrupt Current: 0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC  400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 2,500 cycles: 30 VDC inductive  5,000 cycles: 120 VAC, 400 Hz resistive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load..
$37.94
1 AMP CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals...
$304.46
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals...
$0.00
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 2tc14-1..
$76.03
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-11-17274-11 Series Circuit Breaker | 1 Amp RatingKlixon® 7274-11 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-11 series circuit breaker (Alternate Part# 7274-11-1) is rated for 1 amp. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipment Product CodesMfr Part No:7274-11-1ECCN:EAR99MIL SPEC:MS22073-1NSN:5925-00-912-8343SCHEDULE B CODE:8536.20.0020Weight: 33g, maximum Current Rating: 1 amp Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 1.10V @ 1A..
$44.75
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-2-17274-2 Series Circuit Breaker | 1 Amp RatingKlixon® 7274-2 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-2 series circuit breaker (Alternate Part# 7274-2-1) is rated for 1 amp. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipmentProduct CodesMfr Part No:7274-2-1ECCN:EAR99MIL SPEC:MS26574-1SCHEDULE B CODE:8536.20.0020Weight: 28g, maximum Current Rating: 1 amp Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 1.10V @ 1A..
$34.56
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-4-17274-4 Series Circuit Breaker | 1 Amp RatingKlixon® 7274-4 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-4 series circuit breaker (Alternate Part# 7274-4-1) is rated for 1 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipmentProduct CodesMfr Part No:7274-4-1MIL SPEC:MS26574-1AECCN:EAR99MIL SPEC:MS26574-1ASCHEDULE B CODE:8536.20.0020Weight: 28g, maximum Current Rating: 1 amp Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 0.70V @ 1A..
$70.28
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7277-2-17277-2 Series Circuit Breaker | 1 Amp RatingKlixon 7277-2 series circuit breakers are meant for use in applications that do not require military approvals. The trip-free 7277 was originally developed as an alternative to slow blow fuses and is used extensively as primary electrical circuit protection on general aviation aircraft. The military grade version of this circuit breaker is physically and electrically identical to the Klixon 7277, which has wider calibration limits. Includes hardware.This 7277 series circuit breaker (Alternate Part# 7277-2-1) is rated for 1 amp. Miniature sizeLight weightTrip free designCurrent ratings (0.5 to 20 amps)High vibration resistanceElectrical circuit protection on general aviation aircraftProduct CodesMfr Part No:7277-2-1ECCN:EAR99SCHEDULE B CODE:8536.20.0020Weight: 28 grams, maximum Current Rating: 1 Amp Vibrations: 10G minimum, 50–500 Hz Mechanical shock: 35G Acceleration: 10G Interrupt Current: 0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC  400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 2,500 cycles: 30 VDC inductive  5,000 cycles: 120 VAC, 400 Hz resistive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load..
$32.47
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7277-5-17277-5 Series Circuit Breaker | 1 Amp RatingKlixon 7277 series circuit breakers are meant for use in applications that do not require military approvals. The trip-free 7277 was originally developed as an alternative to slow blow fuses and is used extensively as primary electrical circuit protection on general aviation aircraft. The military grade version of this circuit breaker is the physically and electrically identical Klixon 7277, which has wider calibration limits. Includes hardware.This 7277 series circuit breaker (Alternate Part# 7277-5-1) is rated for 1 amp. Miniature sizeLight weightTrip free designCurrent ratings (0.5 to 20 amps)High vibration resistanceTypical use: computers, construction, data processing and telecommunications equipment, flight simulators, general aviation aircraft, materials handling, industrial electronic equipment, trainers and simulators, where all breakers are operated on low ampere control currentProduct CodesMfr Part No:7277-5-1ECCN:EAR99SCHEDULE B CODE:8536.20.0020Weight: 28 grams, maximum Current Rating: 1 Amp Vibration: 10G minimum, 50Hz – 500Hz (other vibration levels available) Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC, 400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load..
$65.99
1 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. MS3320-12TC2 Series Circuit Breaker | 1 Amp RatingThe 2TC2 series single-phase circuit breakers provide reliable state-of-the-art circuit protection for aerospace power systems. The compact and lightweight design makes these circuit breakers well suited for aircraft avionics and electronic systems. The 2TC series ratings is coordinated so any rating will trip before another rating twice its capacity in the event of a fault. Ambient temperature compensation allows the 2TC circuit breakers to operate where temperatures exceeds the 160°F maximum of non–ambient compensated thermal circuit breakers and may also operate in temperatures as high as 150°F without derating the circuit breaker while eliminating the need for added cooling.  Includes hardware.This 2TC2 circuit breaker (Alternate Part# 2TC2-1) is rated for 1 amps. Compact and lightweightTrip–free designCurrent ratings 1 to 25 ampsHigh vibration resistanceHigh interrupting capacityCoordinated ratingsAS58091 qualified (Also: Military Approvals, FAA PMA)Typical end use: Aircraft power distribution systemsProduct CodesMfr Part No:MS3320-1MIL SPEC:MS3320-1AS:AS58091ECCN:EAR99MIL SPEC:MS3320-1SCHEDULE B CODE:8536.20.0020Weight: 25 g, max. Dimensions: 1.343 x 0.781 x 0.593 in Current Rating: 1 Amp Vibration: 10G, minimum 50 Hz – 500 Hz Mechanical Shock: 50G Acceleration: 10G Sand and Dust: 12 hr Corrosion: salt spray 50 hr Humidity: 10 days Explosion Proof: while interrupting rupture currents Endurance: 2500 cycles: 120 VAC, 400 Hz (inductive) 5000 cycles: 120 VAC, 400 Hz (resistive) 2500 cycles: 30 VDC (inductive) 5000 cycles: 30 VDC (resistive) 10000 cycles: mechanical (no load) Operating Altitude: 70,000 ft..
$37.77
1.5 AMP KLIXON BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-11-1.57274-11 Series Circuit Breaker | 1.5 Amp RatingKlixon® 7274-11 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-11 series circuit breaker (Alternate Part# 7274-111.5) is rated for 1.5 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipment Product CodesMfr Part No:7274-11-1.5MIL SPEC:MS22073-1 1/2ECCN:EAR99MIL SPEC:MS22073-1 1/2NSN:5925009297271SCHEDULE B CODE:8536.20.0020Weight: 33g, maximum Current Rating: 1.5 amps Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 0.70V @ 1.5A..
$41.87
1.5 AMP KLIXON CIRCUIT BREAKER 7277-5-1 1/2. Aircraft circuit breaker. Application: aviation aftermarket general fitment — verify part number against your aircraft IPC before ordering. Cross-reference this part by its manufacturer part number 7277-5-1 1/2 against your aircraft's illustrated parts catalog (IPC) or maintenance manual to confirm direct interchangeability. All inventory ships from our Arizona warehouse with FAA 8130-3 documentation where applicable, and traceability paperwork is available on request for parts requiring it. Live pricing, real-time stock status, and secure online checkout for this part are available at American Aviation Parts...
$72.80
1.5 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-2-1 1/27274-2 Series Circuit Breaker | 1.5 Amp RatingKlixon® 7274-2 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-2 series circuit breaker (Alternate Part# 7274-2-1.5) is rated for 1.5 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipmentProduct CodesMfr Part No:7274-2-1 1/2MIL SPEC:MS26574-1.5ECCN:EAR99MIL SPEC:MS26574-1.5SCHEDULE B CODE:8536.20.0020Weight: 28g, maximum Current Rating: 1.5 amps Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 2.0V @ 1.5A..
$35.14
1.5 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7277-2-1 1/27277-2 Series Circuit Breaker | 1.5 Amp RatingKlixon 7277-2 series circuit breakers are meant for use in applications that do not require military approvals. The trip-free 7277 was originally developed as an alternative to slow blow fuses and is used extensively as primary electrical circuit protection on general aviation aircraft. The military grade version of this circuit breaker is physically and electrically identical to the Klixon 7277, which has wider calibration limits. Includes hardware.This 7277 series circuit breaker (Alternate Part# 7277-2-1.5) is rated for 1.5 amps. Miniature sizeLight weightTrip free designCurrent ratings (0.5 to 20 amps)High vibration resistanceElectrical circuit protection on general aviation aircraftProduct CodesMfr Part No:7277-2-1 1/2ECCN:EAR99SCHEDULE B CODE:8536.20.0020Weight: 28 grams, maximum Current Rating: 1.5 Amps Vibrations: 10G minimum, 50–500 Hz Mechanical shock: 35G Acceleration: 10G Interrupt Current: 0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC  400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 2,500 cycles: 30 VDC inductive  5,000 cycles: 120 VAC, 400 Hz resistive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load..
$33.63
1/2 AMP CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-52-.5..
$357.28
1/2 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals...
$53.77
1/2 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-11-1/27274-11 Series Circuit Breaker | 0.5 Amp RatingKlixon® 7274-11 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-11 series circuit breaker (Alternate Part# 7274-11-.5) is rated for 0.5 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipment Product CodesMfr Part No:7274-11-1/2MIL SPEC:MS22073-1ECCN:EAR99MIL SPEC:MS22073-1NSN:5925009128343SCHEDULE B CODE:8536.20.0020Weight: 33g, maximum Current Rating: 0.5 amps Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 2.00V @ 0.5A..
$44.75
1/2 AMP KLIXON CIRCUIT BREAKER/Includes: Nut-washer key plate and screws for terminals. 7274-2-1/27274-2 Series Circuit Breaker | 0.5 Amp RatingKlixon® 7274-2 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables, and components. The 7274 features a trip–free, indicating reset button and is available in standard ratings from ½ to 20 amps. Includes hardware.This 7274-2 series circuit breaker (Alternate Part# 7274-2-.5) is rated for 0.5 amps. Single-Phase, Non-CompensatedUses minimum spaceLight weightTrip-free designMIL-C-5809 qualifiedLow amp ratingHigh vibration resistanceDesigned to protect military airborne vehicles and equipmentProduct CodesMfr Part No:7274-2-1/2MIL SPEC:MS26574-.5ECCN:EAR99MIL SPEC:MS26574-.5SCHEDULE B CODE:8536.20.0020Weight: 28g, maximum Current Rating: 0.5 amps Vibrations: 10G, minimum, 50 to 500 Hz Mechanical Shock: 35G Acceleration: 10G Interrupt Current: 0.50A – 5A: unlimited @ 28 VDC 7.50A – 15A: 2,000A @ 28 VDC 0.50A – 1.50A: unlimited @ 120 VAC, 400 Hz 2A – 5A: 800A @ 120 VAC, 400 Hz 7.50A – 20A: 500A @ 120 VAC, 400 Hz Endurance: 2,500 cycles: 120 VAC, 400 Hz inductive 5,000 cycles: 120 VAC, 400 Hz resistive 2,500 cycles: 30 VDC inductive 5,000 cycles: 30 VDC resistive 10,000 cycles: Mechanical, no load Voltage Drop (at nominal rated current): 2.0V @ 0.5A..
$32.45
Showing 1 to 0 of 225 (0 Pages)